Dimensions
Pipes - SABS 62 - Dimensions
| Nominal Bore | Approx. Outside Diameter [mm] | Outside Diameter [mm] | Minimum Wall Thickness [mm] | Uncoated Tubes Screwed & Socket [kg/m] |
|||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Light | Medium & Heavy | Light | Medium | Heavy | Light | Medium | Heavy | ||||
| Max | Min | Max | Min | ||||||||
| 6 mm | 10,2 mm | 10,1 | 9,7 | 10,4 | 9,8 | 1,65 | 1,75 | 2,32 | 0,364 | 0,401 | 0,496 |
| 8 mm | 13,5 mm | 13,6 | 13,2 | 13,9 | 13,3 | 1,65 | 2,05 | 2,54 | 0,521 | 0,596 | 0,765 |
| 10 mm | 17,2 mm | 17,1 | 16,7 | 17,4 | 16,8 | 1,65 | 2,05 | 2,54 | 0,680 | 0,888 | 1,055 |
| 15 mm | 21,3 mm | 21,4 | 21,0 | 21,7 | 21,1 | 1,84 | 2,32 | 2,84 | 1,000 | 1,214 | 1,418 |
| 20 mm | 26,9 mm | 26,9 | 26,4 | 27,2 | 26,6 | 2,16 | 2,32 | 2,84 | 1,459 | 1,572 | 1,847 |
| 25 mm | 33,7 mm | 33,8 | 33,2 | 34,2 | 33,4 | 2,44 | 2,84 | 3,54 | 2,255 | 2,398 | 2,955 |
| 32 mm | 42,4 mm | 42,5 | 41,9 | 42,9 | 42,1 | 2,44 | 2,84 | 3,54 | 2,890 | 3,076 | 3,813 |
| 40 mm | 48,3 mm | 48,4 | 47,8 | 48,8 | 48,0 | 2,67 | 2,84 | 3,54 | 3,294 | 3,509 | 4,359 |
| 50 mm | 60,3 mm | 60,2 | 59,6 | 60,8 | 59,8 | 2,67 | 3,19 | 3,94 | 4,446 | 5,125 | 6,069 |
| 65 mm | 76,1 mm | 76,0 | 75,2 | 76,6 | 75,4 | 3,00 | 3,19 | 3,94 | 6,050 | 6,574 | 7,804 |
| 80 mm | 88,9 mm | 88,7 | 88,9 | 89,5 | 88,1 | 3,00 | 3,54 | 4,24 | 7,149 | 8,389 | 9,839 |
| 100 mm | 114,3 mm | 113,9 | 113,0 | 114,9 | 113,3 | 3,36 | 3,94 | 4,73 | 10,127 | 10,082 | 14,172 |
| 125 mm | 139,7 mm | - | - | 140,6 | 138,7 | - | 4,24 | 4,73 | - | 15,868 | 17,563 |
| 150 mm | 165,1 mm | - | - | 166,1 | 164,1 | - | 4,24 | 4,73 | - | 17,148 | 20,964 |
- For the approximate mass of galvanised tubes, add the following percentages to mass indicated above:
Light Tube – 6.5%; Med Tube – 5.75%; Heavy Tube – 5% - Tolerance:
Outside Diameters – see max & min above; Thickness – plus tolerances
Recommended Working Pressures
Maximum working pressure in kPa. Taper/parallel joint
Pipes - SABS 62 - Recommended Working Pressures
| Nominal Bore | Water service at ambient temperature | Steam, air and gas service [260ÂșC maximum] |
|||
|---|---|---|---|---|---|
| Light | Medium | Heavy | Medium | Heavy | |
| 6 mm | 1 050 | 2 100 | 2 400 | 1 050 | 1 200 |
| 8 mm | 1 050 | 2 100 | 2 400 | 1 050 | 1 200 |
| 10 mm | 1 050 | 2 100 | 2 400 | 1 050 | 1 200 |
| 15 mm | 1 050 | 2 100 | 2 400 | 1 050 | 1 200 |
| 20 mm | 1 050 | 2 100 | 2 400 | 1 050 | 1 200 |
| 25 mm | 1 050 | 2 100 | 2 400 | 1 050 | 1 200 |
| 32 mm | 850 | 1 700 | 2 100 | 850 | 1 050 |
| 40 mm | 850 | 1 700 | 2 100 | 850 | 1 050 |
| 50 mm | 700 | 1 400 | 1 700 | 700 | 850 |
| 65 mm | 700 | 1 400 | 1 700 | 700 | 850 |
| 80 mm | 700 | 1 400 | 1 700 | 700 | 850 |
| 100 mm | 550 | 1 050 | 1 400 | 550 | 700 |
| 125 mm | - | 1 050 | 1 400 | 550 | 700 |
| 150 mm | - | 850 | 1 050 | 400 | 550 |
- These pipes can be used for higher pressures than those above, or for special working conditions with suitable types of joints.
- The efficiency of taper/parallel screwed joints is highly dependant on the degree of care taken in assembly and jointing compound used.
- Light pipes are not recommended for steam, air or gas services. Reference to steam service applies to saturated steam only.